Pressure, Vacuum and Temperature Specifications
Switch F129 - Clutch On/Off Pressures| Low Pressure Cut-Out | High Pressure Cut-Out | ||
| Compressor Clutch | Opens (Off) | 1.2 | 32 |
| Closes (On) | 2.4 | 24 |
| Radiator Cooling Fan | Opens (2nd Speed Off) | 12.5 |
| Closes (2nd Speed On) | 16 |
| Coolant Temperature | |
| Opens (3rd Speed Off) | 108 C |
| Closes (3rd Speed On) | 112 C |