Inspection
2GR-FE ENGINE CONTROL SYSTEM: CAMSHAFT OIL CONTROL VALVE: INSPECTION
1. INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
(a) Using an ohmmeter, measure the resistance between the terminals.
(b) Connect the battery's positive (+) lead to terminal 1 and negative (-) lead to terminal 2. Check the movement of the valve.
OK:
If operation is not as specified, replace the valve.