Canister Purge Solenoid: Testing and Inspection
1ZZ-FE EMISSION CONTROL: PURGE VALVE:
INSPECTION
1. INSPECT VACUUM SWITCHING VALVE ASSEMBLY NO. 1
(a) Check the resistance.
(1) Using an ohmmeter, measure the resistance between the terminals.
Resistance:
If the resistance is not as specified, replace the vacuum switching valve No. 1.
(b) Check the vacuum switching valve No. 1 for ground.
(1) Using an ohmmeter, check the resistance between each terminal and the body.
Resistance:
If the resistance is not as specified, replace the vacuum switching valve No. 1.
(c) Check the operation.
(1) Check that air does not flow from port E to F.
If the operation is not as specified, replace the vacuum switching valve No. 1.
(2) Apply battery voltage across the terminals.
(3) Check that air flows from port E to port F.
If the operation is not as specified, replace the vacuum switching valve No. 1.