Blower Motor: Testing and Inspection
INSPECTION1. REMOVE GLOVE COMPARTMENT PARTS
2. REMOVE BLOWER MOTOR
a. Disconnect the connector.
b. Remove the 3 screws and blower motor.
3. INSPECT BLOWER MOTOR OPERATE
Connect the positive (+) lead from the battery to terminal 2 and negative (-) lead to terminal 1, then check that the motor operations smoothly.
If operation is not as specified, replace the blower motor.
4. INSTALL BLOWER MOTOR
a. Install the blower motor with the 3 screws.
b. Connect the connector.
5. INSTALL GLOVE COMPARTMENT PARTS