Intermittent Wiper Operation
INSPECT INTERMITTENT OPERATION1. Turn the wiper switch to the INT position.
2. Connect the positive (+) lead from the battery to terminal 17 and the negative (-) lead to terminal 2.
3. Connect the positive (+) lead from the voltmeter terminal 16 and the negative (-) lead to terminal 7, and check that the meter needle indicates battery voltage.
4. After connecting terminal 16 to terminal 17. connect terminal 16 to terminal 2. Then, check that the voltage rises from 0 V to battery voltage within the specified limes, as follows.
If operation is not as specified, replace the switch.