Service Hints
P 8 POWER WINDOW MASTER SW
4-GROUND: Approx. 12 Volts with Ignition SW at ON position
8-GROUND: Always Continuity
10-GROUND: Approx. 12 Volts with Ignition SW ON and Master SW (Driver's Window) at UP position
9-GROUND: Approx. 12 Volts with Ignition SW ON and Master SW (Driver's Window) at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with the Window Lock SW at LOCK position