Thermal Vacuum Valve - EVAP: Testing and Inspection
THERMAL VACUUM VALVE (TVV) INSPECTION1. DRAIN ENGINE COOLANT
2. REMOVE TVV FROM INTAKE MANIFOLD
3. INSPECT TVV OPERATION
- Cool the TVV to below 4O°C (104°F) with cool water.
- Check that air does not flow from the upper port to lower port.
- Heat the TVV to above 59°C (138°F) with hot water.
- Check that air flows from the upper port to lower port.
- If operation is not as specified, replace the TVV.
4. REINSTALL TVV
- Apply adhesive to 2 or 3 threads of the TVV, and install it.
- Adhesive: Part No. 08833-00070, THREE BONE) 1324 or equivalent
Torque: 30 Nm (305 kgf.cm. 22 ft.lb)
5. REFILL WITH ENGINE COOLANT