Circuit Description
Current is applied always through POWER Fuse to TERMINAL 5 of Power Main Relay and also through DOME fuse to TERMINAL 12 of Moon Roof control relay.
With the Ignition SW turned ON, current flows through GAUGE Fuse to TERMINAL 1 of Power Main Relay --> TERMINAL 2 --> GROUND. As a result, Power Main Relay is activated and the current flows to TERMINAL 5 of Power Main Relay to TERMINAL 3 of the relay --> TERMINAL 6 of Moon Roof control relay.
1. SLIDE OPEN OPERATION
When the Ignition SW is turned ON and the Moon Roof control SW is pushed to the OPEN position, a signal is input from TERMINAL 3 of Moon Roof control SW to TERMINAL 1 of Moon Roof control relay, turning the Moon Roof limit SW No.2 ON
When this occurs, the relay is activated and the current to TERMINAL 6 of Moon Roof control relay flows from TERMINAL 5 --> TERMINAL 1 of Moon Roof motor --> TERMINAL 3 --> TERMINAL 4 of the Relay --> TERMINAL 11 --> GROUND, rotating the motor to open the Moon Roof while the SW is being pushed to OPEN position.
2. SLIDE CLOSE OPERATION
With the Ignition SW turned ON, the Moon Roof completely open and Moon Roof limit SW No.1 and No.2 both ON, when the Moon Roof control SW is pushed to the CLOSE position a signal is input from TERMINAL 6 of Moon Roof control SW to TERMINAL 2 of Moon Roof control relay.
When this occurs, the relay is activated and the current to TERMINAL 6 of Moon Roof control relay flows from TERMINAL 4 --> TERMINAL 3 of Moon Roof motor --> TERMINAL 1 --> TERMINAL 5 of the relay --> TERMINAL 11 --> to GROUND rotating the motor to close the Moon Roof while the SW is being pushed to CLOSE position.
When the Moon Roof limit SW No.1 is turned OFF (limit SW No.2 is ON) and a 100 mm before fully CLOSE position, signal is input from TERMINAL 1 of limit SW No.1 into TERMINAL 8 of Moon Roof control relay. This signal activates the relay and stops continuity from TERMINAL 6 of Moon Roof control relay to TERMINAL 11 --> to GROUND. As a result, the Moon Roof stops at this position.
To close the Moon Roof completely, pushing the Moon Roof control SW again to the close side causes a signal to be input again to TERMINAL 2 of Moon Roof control relay. This activates the relay and the Moon Roof will close as long as the Moon Roof control SW is being pushed, allowing the Moon Roof to completely close.
3. TILT UP OPERATION
When the Moon Roof control SW is pushed to TILT UP position, with the Ignition SW turned ON and the Moon Roof completely closed (Moon Roof limit SW No.2 is OFF), a signal is input from TERMINAL 5 of Moon Roof control SW into TERMINAL 3 of Moon Roof control relay. As a result, the relay is activated and the current to TERMINAL 6 of relay flows from TERMINAL 4 of relay --> TERMINAL 3 of Moon Roof motor --> TERMINAL 1 --> TERMINAL 5 of relay --> TERMINAL 11 --> GROUND rotating the motor so that tilt up operation occurs as long as the Moon Roof control SW is pushed ON the tilt up side.
4. TILT DOWN OPERATION
When the Moon Roof control SW is pushed to TILT DOWN position, with the Ignition SW turned ON and the Moon Roof tilted up (No.1 and No.2 Moon Roof limit switches are both OFF), a signal is input from TERMINAL 2 of the Moon Roof control SW into TERMINAL 7 of the Moon Roof control relay.
As a result, the relay is activated and the current to TERMINAL 6 of the relay flows from TERMINAL 5 of the relay --> TERMINAL 1 of Moon Roof motor --> TERMINAL 3 --> TERMINAL 4 of relay --> TERMINAL 11 --> GROUND rotating the motors so that tilt down operation occurs as long as the Moon Roof control SW is pushed on the tilt down side. (during tilt down, limit SW No.1 is changed OFF to ON.)