FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Leak Detection Sensor, Evaporative System

Voltage at connector: (sensor disconnected)
VC - E2 4.5 - 5.5 Volts

Voltage at sensor (sensor connected, vacuum/pressure applied)
None 2.9 - 3.7 Volts
2.0 kpa, 15 mm Hg, 0.59 in.Hg 1.3 - 2.1 Volts
1.5 kpa, 15 gf/cm2, 0.22 psi 4.2 - 4.8 Volts