Air Flow Meter/Sensor

THA - E2
Resistance Temperature

10 - 20 k Ohms -20°C (-4°F)
4 - 7 k Ohms 0°C (32°F)
2 - 3 k Ohms 20°C (68°F)
0.9 - 1.3 k Ohms 40°C (104°F)
0.4 - 0.7 k Ohms 60°C (140°F)
0.2 - 0.4 k Ohms 80°C (176°F)