Knock Sensor: Testing and Inspection
KNOCK SENSORS INSPECTION1. REMOVE AIR CLEANER HOSE.
2. REMOVE RH ENGINE MOUNTING STAY.
3. REMOVE WATER OUTLET.
4. REMOVE KNOCK SENSORS.
- Disconnect the knock sensor connector.
- Using SST, remove the knock sensor.
- SST 09817-16011
5. INSPECT KNOCK SENSORS.
- Using an ohmmeter, check that there is no continuity between the terminal and body.
- If there is continuity, replace the sensor.
6. REINSTALL KNOCK SENSORS.
- Using SST, install the knock sensor.
Torque: 39 Nm (400 kgf.cm, 29 ft.lb)
- Connect the knock sensor connector.
7. REINSTALL WATER OUTLET.
8. REINSTALL RH ENGINE MOUNTING STAY.
9. REINSTALL AIR CLEANER HOSE.