Wastegate Solenoid: Testing and Inspection
VACUUM SWITCHING VALVE (VSV) INSPECTION1. REMOVE VSV ASSEMBLY.
2. INSPECT VSV.
A. Inspect VSV for open circuit.
- Using an ohmmeter, check that there is continuity between the terminals.
Resistance at 20°C (68°F): 22 - 26 Ohms
- If there is no continuity, replace the VSV.
B. Inspect VSV for ground.
- Using an ohmmeter, check that there is no continuity between each terminal and the body.
- If there is continuity, replace the VSV.
C. Inspect VSV operation.
- Check that air does not flow from port E to port F.
- Apply battery voltage across the terminals.
- Check that air flows from ports E to F.
- If operation is not as specified, replace the VSV.
3. REINSTALL VSV ASSEMBLY.