Fan Relay Number 3
Clutch Relay And Condenser Relay Number 3 Internal Schematics:
RELAY TERMINAL ID AND SCHEMATIC
Clutch Relay And Condenser Relay Number 3 Testing:
INSPECT RELAY OPERATION
With No Power Applied
Continuity should exist between terminals 1 and 3. If not as specified, replace the relay.
With Power Applied
With power applied to terminals 3 and 1, continuity should exist between terminals 2 and 4. If not as specified, replace the relay.