Spool Release Switch
Spool Release Switch:
1. Disconnect spool release switch connector. Ensure continuity between terminals with release lever pulled up.
2. Ensure no continuity between terminals with release lever pushed down.
3. If continuity is not as specified, replace spool release switch.