Removal and Installation
COMPONENTS
REMOVAL
1. DISCONNECT GENERATOR CONNECTOR AND WIRE
a. Disconnect the generator connector.
b. Remove the nut, and disconnect the generator wire.
Torque: 9.8 Nm (100 kg.cm, 7.2 ft.lb)
c. Disconnect the wire harness with the clip.
2. REMOVE GENERATOR DRIVE BELT
a. Loosen the adjusting lock bolt and pivot bolt.
b. Loosen the adjusting bolt, and remove the drive belt.
3. REMOVE GENERATOR
a. Remove the pivot bolt and adjusting lock bolt.
Torque:
59 Nm (600 kg.cm, 43 ft.lb) for pivot bolt
29 Nm (300 kg.cm, 21 ft.lb) for adjusting lock bolt
b. Remove the generator.
INSTALLATION
Installation is in the reverse order of removal.