SDM Inspection
SDM Inspection
SDM Removal and Installation
NOTE:
The SDM may not function properly if you do not handle it carefully.
- Do not connect any type of tester to the SDM.
- Never try to repair or disassemble the SDM.
- Replace the SDM if it has been dropped.
If any faulty condition is found in the following checks, replace them with new one.
- Air bag is deployed.
- Check SDM for dents, cracks or deformation.
- Check SDM connector for damage, cracks or lock mechanism.
- Check SDM terminal for bend, corrosion or rust.
- DTC B1013, B1021, B1024, B1025, B1026, B1028, B1029, B1220 or B1221 is stored in SDM.