Wastegate Solenoid: Service and Repair
Wastegate Control Solenoid ValveREMOVAL
1. Remove the collector cover.
2. Disconnect the ground cable from battery.
3. Disconnect the connector (A) from the wastegate control solenoid valve.
4. Disconnect the vacuum hose (B) and air control hose (C) from the wastegate control solenoid valve.
5. Remove the wastegate control solenoid valve from the bracket.
INSTALLATION
Install in the reverse order of removal.
Tightening torque: 6.4 N.m (0.7 kgf.m, 4.7 ft.lb)