Purge Control Solenoid Valve
Purge Control Solenoid ValveREMOVAL
1. PURGE CONTROL SOLENOID VALVE 1
1. Remove the collector cover.
2. Disconnect the ground cable from battery.
3. Remove the bolts which secure purge control solenoid valve 1 to the intake manifold, and disconnect the connector from the purge control solenoid valve 1.
4. Disconnect the vacuum hose from purge control solenoid valve 1.
2. PURGE CONTROL SOLENOID VALVE 2
1. Remove the collector cover.
2. Disconnect the ground cable from battery.
3. Remove the solenoid valve bracket assembly from the intake manifold.
4. Disconnect the connector and the vacuum hose from purge control solenoid valve 2.
5. Remove the purge control solenoid valve 2 from the solenoid valve bracket assembly.
INSTALLATION
1. PURGE CONTROL SOLENOID VALVE 1
Install in the reverse order of removal.
NOTE: Connect the vacuum hose as shown in the figure.
Tightening torque: 6.4 N.m (0.7 kgf.m, 4.7 ft.lb)
2. PURGE CONTROL SOLENOID VALVE 2
Install in the reverse order of removal.
NOTE: Connect the vacuum hose as shown in the figure.
Tightening torque: 6.4 N.m (0.7 kgf.m, 4.7 ft.lb)
Tightening torque:
T1: 17 N.m (1.7 kgf.m, 12.5 ft.lb)
T2: 19 N.m (1.9 kgf.m, 14.0 ft.lb)