Coolant Reservoir: Service and Repair
Reservoir TankREMOVAL
1. Disconnect the over flow hose.
2. Remove the bolts which hold the reservoir tank to the fan shroud, then remove the reservoir tank.
INSTALLATION
Install in the reverse order of removal.
Tightening torque: 7.5 N�m (0.8 kgf-m, 5.5 ft-lb)
INSPECTION
Make sure the engine coolant level is between "FULL" and "LOW".