Canister Purge Solenoid: Service and Repair
Purge Control Solenoid ValveREMOVAL
1. Remove the collector cover.
2. Disconnect the ground cable from battery.
3. Remove the air intake chamber.
4. Disconnect the connector and hoses of purge control solenoid valve, and then remove the purge control solenoid valve.
INSTALLATION
Install in the reverse order of removal.
NOTE: Connect the evaporation hose as shown in the figure.