Variable Induction Control Valve: Service and Repair

Tumble Generator Valve Assembly

REMOVAL
1. Release the fuel pressure.
2. Open the fuel filler lid and remove the fuel filler cap.




3. Disconnect the ground cable from battery.
4. Remove the intake manifold.




5. Disconnect the connectors from the tumble generator (A) and tumble generator valve actuator (B).
6. Remove the fuel injector.




7. Remove the tumble generator valve body from the intake manifold.

INSTALLATION




Install in the reverse order of removal.

NOTE: Always use new gaskets.