Wiper Motor Linkage: Service and Repair
Front Wiper Motor and LinkREMOVAL
1. Disconnect the ground cable from battery.
2. Remove the cowl panel.
3. Disconnect the connector of wiper motor assembly.
4. Remove the bolt to remove wiper assembly.
NOTE: Wiper motor and wiper link can not be disassembled, because those are assembly part.
INSTALLATION
Install in the reverse order of removal.
Tightening torque:
T1: 6.0 N.m (0.61 kgf-m, 4.4 ft-lb)
T2: 20 N.m (2.0 kgf-m, 14.5 ft-lb)