P0134
DTC P0134 - O2 SENSOR CIRCUIT NO ACTIVITY DETECTED (BANK 1 SENSOR 1)OUTLINE OF DIAGNOSIS
Detect the open circuit of front oxygen (A/F) sensor heater. Diagnosis is performed using front oxygen (A/F) sensor IC, and communication is established between front oxygen (A/F) sensor IC and main IC. Front oxygen (A/F) sensor judges NG when the impedance of front oxygen (A/F) sensor is abnormal.
COMPONENT DESCRIPTION
ENABLE CONDITION
GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.
DIAGNOSTIC METHOD
Front oxygen (A/F) sensor judges NG when the continuous time until completing the malfunction criteria becomes more than the time needed for diagnosis (5 seconds). Front oxygen (A/F) sensor judges OK and clear NG when the malfunction criteria are not completed.
DTC CLEAR CONDITION
- When the OK idling cycle was completed 40 times in a row
- When "Clear Memory" was performed
MALFUNCTION INDICATOR LIGHT CLEAR CONDITION
- When the OK driving cycle was completed 3 times in a row
- When "Clear Memory" was performed
FAIL SAFE
- Front oxygen (A/F) sensor IC communication: Not allowed to communicate
- Front oxygen (A/F) sensor main learning correction: Not allowed to calculate
- Correction when re-starting at high temperature: Normally minimum value 0.06 -> 0.
- Purge control: Not allowed to purge
ECM OPERATING AT DTC SETTING
Memorize the freeze frame data. (For test mode $02)