Neutral Safety Switch: Adjustments
Inhibitor SwitchADJUSTMENT
1. Loosen the three inhibitor switch securing bolts.
2. Shift the select lever to the N range.
3. Insert ST as vertical as possible into the holes in the inhibitor switch lever and switch body.
ST 499267300 STOPPER PIN
4. Tighten the three inhibitor switch bolts.
Tightening torque: 3.5 Nm (0.36 kgf-cm, 2.6 ft. lbs.)
5. Repeat the above checks. If the inhibitor switch is determined to be "faulty", replace it.