Variable Induction Control Solenoid: Service and Repair
REMOVAL1. Disconnect battery ground cable.
2. Remove intake manifold.
3. Disconnect connector from induction valve control solenoid.
4. Remove induction valve control solenoid from intake manifold.
INSTALLATION
Install in the reverse order of removal.
CAUTION: Always use a new gasket.
Tightening torque: 19 N.m (1.9 kgf-m, 14 ft-lb)