Test 10C1
TEST 10C1: CHECK GENERATOR
1) Start the engine.
2) Idle the engine.
3) Measure voltage between generator and chassis ground.
Terminal: Generator B terminal (+) & Chassis ground (-)
CHECK: Is the voltage between 10 and 15 Volts?
YES: Test 10C2
NO: Repair generator.