DTC 62
OVERVIEW
Faulty inlet solenoid valve circuit(s) and Traction Control System (TCS) solenoid valve circuit(s) in hydraulic unit are indicated.
DIAGNOSIS
^ Faulty harness/connector.
^ Faulty solenoid valve in hydraulic unit.
^ Faulty ABS/TCS control module.
TROUBLE SYMPTOM
^ ABS does not operate.
^ TCS does not operate.
^ ABS sequence control does not operate.
^ TCS sequence control does not operate.
PROCEDURE
1. Check resistance of solenoid valve.
a) Turn ignition switch OFF.
b) Disconnect connector from hydraulic unit.
c) Measure resistance between hydraulic unit terminals.
TROUBLE CODE / Connector & terminal:
31 / (F15) No. 3 & No. 9
33 / (F15) No. 4 & No. 10
35 / (F15) No. 1 & No. 10
37 / (F15) No. 2 & No. 9
61 / (F15) No. 12 & No. 9
62 / (F15) No. 11 & No. 10
Specified resistance: approx. 6 ± 0.5 ohms
2. Check body short of solenoid valve.
a) Turn ignition switch OFF.
b) Disconnect connector from hydraulic unit.
c) Measure resistance between hydraulic unit terminals.
TROUBLE CODE / Connector & terminal:
31 / (F15) No. 3 & body
33 / (F15) No. 4 & body
35 / (F15) No. 1 & body
37 / (F15) No. 2 & body
61 / (F15) No. 12 & body
62 / (F15) No. 11 & body
Specified resistance: approx. 1 M ohm
3. Check body short of harness.
a) Turn ignition switch OFF.
b) Disconnect connector from hydraulic unit.
c) Disconnect connector from ABS/TCS control module.
d) Measure resistance between ABS/TCS control module connector terminals.
TROUBLE CODE / Connector & terminal:
31 / (P5) No. 2 & body
33 / (P4) No. 2 & body
35 / (P4) No. 4 & body
37 / (P5) No. 7 & body
61 / (P4) No. 5 & body
62 / (P5) No. 6 & body
Specified resistance: 1 M ohm
4. Check harness between ABS/TCS control module and hydraulic unit.
a) Turn ignition switch OFF.
b) Connect connector from hydraulic unit.
c) Disconnect connector from ABS/TCS control module.
d) Measure resistance between ABS/TCS control module connector terminals.
TROUBLE CODE / Connector & terminal:
31 / (P5) No. 2 & (P6) No. 6
33 / (P4) No. 2 & (P6) No. 6
35 / (P4) No. 4 & (P6) No. 6
37 / (P5) No. 7 & (P6) No. 6
61 / (P4) No. 5 & (P6) No. 6
62 / (P5) No. 6 & (P6) No. 6
Specified resistance: 6.2 ± 0.5 ohms