Troubleshooting Procedure









1. BASIC INSPECTION
a. Check battery voltage.
b. Check fuses No. 8, 15 (in F/B) and 25 (in M/B).

2. READ MEMORY
a. Turn ignition switch "OFF."
b. Connect male terminal to diagnosis connector mode terminal No. 6.
b. Start engine.
c. Disconnect male terminal from diagnosis connector mode terminal No. 6.

3. D CHECK
a. Turn ignition switch "OFF.
b. Connect male terminal to diagnosis connector mode terminal No. 5.
c. Start engine.
d. Drive vehicle at least 10 meters (33 ft).
e. Disconnect male terminal from diagnosis connector mode terminal No. 5.

4. CLEAR MEMORY
a. Turn ignition switch "OFF."
b. Connect male terminals to diagnosis connector mode terminals No 5 and 6.
c. Start engine.
d. Disconnect male terminals from diagnosis connector mode terminals No. 5 and 6
e. Ensure that memory is cleared in read memory mode.