Inhibitor Switch Check
1. Disconnect cable end from selector lever.2. Disconnect [1][2]inhibitor switch connector.
3. Check continuity in [1][2]inhibitor switch circuits with selector lever moved to each position. Also check that continuity in ignition circuit does not exist when selector lever is in R. 3, 2 and 1 ranges.
4. Check if there is continuity at equal points when the selector lever is turned 1.5° in both directions from the N range. If there is continuity in one direction and the continuity in the other or if there is continuity at unequal points, adjust the [1][2]inhibitor switch.