Auxiliary Purge Control Valve
Auxiliary Purge Control Valve:
1. Confirm that air does not pass between fittings.
2. Apply 42 kPa (13 in Hg) pressure to fitting A. Air should pass between fittings B and C.
Replace the valve if it fails the above tests.