AR00.19-P-0120-28A Remove contacts from YAZAKI 1.5 system coupling



AR00.19-P-0120-28A Remove Contacts From YAZAKI 1.5 System Coupling







220 589 04 99 00, Unfasten secondary release with safety frame







000 589 13 99 00, Wiring harness repair kit, basic







220 589 01 99 50, Blade holder with clamping pliers







220 589 01 99 60, MQS blade

Unfasten secondary release with safety frame







1 Use suitable tool to remove safety frame (2).
Avoid inserting the tool too far to prevent damaging the seal in the rear part of the coupling (1).

Remove female contact from coupling







2 Insert blade holder with clamping pliers and MQS blade from front side though lower opening at contact cavity of coupling (1).
This then presses the spring shackle downwards.
3 Pull lightly on the corresponding line to remove the female contact (2) from the coupling (1).
Rocking the female contact (2) back and forth making use of the housing tolerance may help to unpin the contact.