AR00.19-P-0120-30A Remove female contact from double flat spring contact coupling
AR00.19-P-0120-30A Remove Female Contact From Double Flat Spring Contact Coupling
220 589 04 99 00, New passenger vehicle wiring harness repair kit
000 589 13 99 00, Wiring harness repair kit, basic
220 589 01 99 50, Blade holder with clamping pliers
220 589 01 99 56, LSK 8 blade
220 589 01 99 51, MPT blade
Unfasten secondary release on version with locking grille
1 Insert a suitable tool on side between locking grille (1) and housing.
2 Slide locking grille (1) in direction of arrow .
Unfasten secondary release on version with slide
3 Insert a suitable tool on side between slide (1) and housing.
4 Move slide (1) in direction of arrow .
Unfasten secondary release on version with slide
5 Push (1) slider out of locked position in direction of arrow.
Unpin female contacts from coupling (Version 1)
6 Insert blade holder with clamping pliers and LSK 8 blade from front side though openings at contact cavity of coupling.
This pushes together the springs at the female contact (1).
7 A slight tug on the corresponding cable will remove the female contact (1) from the coupling.
Unpin female contacts from coupling (Version 2)
8 Insert blade holder with clamping pliers and MPT blade from front side though openings at contact cavity of coupling.
This presses together the springs of the female contact (1).
9 A slight tug on the corresponding cable will remove the female contact (1) from the coupling.