AR00.19-P-0120-23A Remove contacts from Siemens ELO coupling
AR00.19-P-0120-23A Remove Contacts From Siemens ELO Coupling
220 589 04 99 00, New passenger vehicle wiring harness repair kit
000 589 13 99 00, Wiring harness repair kit, basic
220 589 01 99 50, Blade holder with clamping pliers
220 589 01 99 60, MQS blade
Unfasten secondary release on version with secondary retainer
1 Use a suitable tool to reach into the secondary lock (1) and slide in direction of arrow towards pre-locking position (1a).
Unfasten secondary release on version with securing clip
2 Using a suitable tool, pry up the side tabs of the retaining clamp (1).
3 Slide securing clip (1) upwards.
4 Remove securing clip (1).
Unpin female contacts from coupling
5 Attach blade holder with clamping pliers and MQS blade at side of spring shackle of female contact (2).
6 Press the spring shackle of the female contact (2) downward and push the female contact (2) out of the contact cavity of the connector housing (1). Tug the corresponding cable at the same time to assist the unpinning procedure.