AN82.10-P-0008-02MCC Retrofit BRABUS Longitudinal Member Panel Illumination Wiring Harness
AN82.10-P-0008-02MCC Retrofit BRABUS Longitudinal Member Panel Illumination Wiring Harness
Routing diagram
3 Lamp units
6 Wiring harness
10 Connector
E15/4 Front interior lamp
N10/10 SAM control unit
Connection diagram
1 Right longitudinal member panel
2 Left longitudinal member panel
3 Headlamp unit
4 Fuse holder
6 Wiring harness
7 Clutch
8 Connector
9 Adapter wiring harness
10 Connector
11 Clutch
12 Clutch
13 Connector
14 Connector
15 Clutch
16 Coupling (vehicle wiring harness)
E15/4 Front interior lamp
N10/10 SAM control unit
Route wiring harness (6) such that it cannot be damaged by chafing or crushing.
Special attention must be paid to the line routing in the vicinity of the wiper system since the wiper linkage must have clearance in every position.
Failure to observe this can result in short circuit or the wiper system locking up.
1. Route branch-off line of wiring harness (6) from right longitudinal member along vehicle wiring harness up to center of firewall.
The installation position of the individual branch-off lines is defined by the different length.
2. Route branch-off line of wiring harness (6) along vehicle wiring harness from center of firewall to left longitudinal member.
The installation position of the individual branch-off lines is defined by the different length.
3. Fasten branch-off lines of wiring harness (6) using cable ties at vehicle wiring harness.
4. Carefully cut off a rubber plug of grommet (16).
5. Route interior compartment branch-off line of wiring harness (6) through opening in grommet (16) into interior.
6. Seal grommet (16) using suitable sealant.
7. Route interior compartment branch-off line of wiring harness (6) along broken line to SAM control unit and to roof paneling.
The installation position of the individual branch-off lines is defined by the different length.
8. Fasten interior compartment branch-off line using cable ties at vehicle wiring harness.
9. Plug electrical lines (17) of wiring harness (6) into coupling (7) in accordance with electrical lines (18) of adapter wiring harness (9).
To prevent polarity reversal of electrical lines (17) and electrical lines (18), electrical lines (17, 18) have the same color coding.
10. Establish electrical connection with connector (8) and coupling (7).
11. Connect coupling (11) of adapter wiring harness (9) to front interior lamp (E15/4).
12. Connect connector (10) of adapter wiring harness (9) to coupling (16).
13. Fasten adapter wiring harness (9) with cable ties.
14. Remove screws/bolts (19) at SAM control unit (N10/10).
15. Unclip SAM control unit (N10/10) in rear area (arrow).
16. Plug branch-off line of wiring harness into fuse holder (4).
17. Insert fuse holder (4) into free slot at SAM control unit (N10/10) and insert a fuse with a fuse rating of 5 amps.
The slots are coded.
18. Clip SAM control unit (N10/10) into rear area (arrow A) and screw down using screws/bolts (19).