Installation
FA20 EMISSION CONTROL: PCV VALVE: INSTALLATION; 2013 MY FR-S [03/2012 -]
1. INSTALL PCV VALVE SUB-ASSEMBLY
(a) Apply adhesive to 2 or 3 threads of the PCV valve sub-assembly.
Adhesive:
Three Bond 1141G or equivalent
(b) Using a 19 mm deep socket wrench, install the PCV valve sub-assembly.
Torque : 23 Nm (235 kgf-cm, 17 ft-lbf)
(c) Connect the ventilation hose.
2. INSTALL INTAKE MANIFOLD
Installation