Removal
1NR-FE ENGINE CONTROL: CAMSHAFT OIL CONTROL VALVE: REMOVAL
1. REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
(a) for Exhaust Side:
(1) Disconnect the connector of the camshaft timing oil control valve assembly.
(2) Remove the bolt and the camshaft timing oil control valve assembly.
NOTICE:
If a component has been dropped or subjected to a strong impact, replace it.
(3) Remove the O-ring from the camshaft timing oil control valve assembly.
(b) for Intake Side:
(1) Disconnect the connector of the camshaft timing oil control valve assembly.
(2) Remove the bolt and the camshaft timing oil control valve assembly.
NOTICE:
If a component has been dropped or subjected to a strong impact, replace it.
(3) Remove the O-ring from the camshaft timing oil control valve assembly.