Removal
METER: COMBINATION METER: REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
2. REMOVE INSTRUMENT CLUSTER FINISH PANEL
(a) Disengage the 8 claws and 5 clips and remove the cluster finish panel.
3. REMOVE COMBINATION METER ASSEMBLY
(a) Disconnect the 2 connectors and remove the 2 screws.
(b) Disengage the 2 clips and remove the combination meter assembly.