Removal
2AZ-FE EMISSION CONTROL: PURGE VALVE: REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Testing and Inspection.
2. REMOVE NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
(a) Disconnect the connector.
(b) Remove the wire harness clamp.
(c) Disconnect the 2 purge line hoses from the No. 1 vacuum switching valve assembly.
(d) Remove the No. 1 vacuum switching valve assembly from the air cleaner hose.