Installation
2AZ-FE EMISSION CONTROL: AIR FUEL RATIO SENSOR: INSTALLATION
1. INSTALL AIR FUEL RATIO SENSOR (for Bank 1 Sensor 1)
(a) Using SST, install the sensor to the exhaust manifold.
SST : 09224-00010
Torque : 40 Nm (408 kgf-cm, 30 ft-lbf for use with SST)
Torque : 44 Nm (449 kgf-cm, 32 ft-lbf for use without SST)
HINT
Use a torque wrench with a fulcrum length of 30 cm (11.81 in.).
(b) Connect the sensor connector.
2. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Testing and Inspection.
3. INSPECT FOR EXHAUST GAS LEAK