P0113
2AZ-FE ENGINE CONTROL SYSTEM: SFI SYSTEM: P0110: Intake Air Temperature Circuit
DTC P0110 - Intake Air Temperature Circuit
DTC P0112 - Intake Air Temperature Circuit Low Input
DTC P0113 - Intake Air Temperature Circuit High Input
DESCRIPTION
The Intake Air Temperature (IAT) sensor, mounted on the Mass Air Flow (MAF) meter, monitors the IAT. The IAT sensor has a built-in thermistor with a resistance that varies according to the temperature of the intake air. When the IAT is low, the resistance of the thermistor increases. When the temperature is high, the resistance drops. These variations in resistance are transmitted to the ECM as voltage changes (see Fig. 1).
The IAT sensor is powered by a 5 V supply from the THA terminal of the ECM, via resistor R.
Resistor R and the IAT sensor are connected in series. When the resistance value of the IAT sensor changes, according to changes in the IAT, the voltage at terminal THA also varies. Based on this signal, the ECM increases the fuel injection volume when the engine is cold to improve driveability.
HINT: When any of DTCs P0110, P0112 and P0113 are set, the ECM enters fail-safe mode. During fail-safe mode, the IAT is estimated to be 20°C (68°F) by the ECM. Fail-safe mode continues until a pass condition is detected.
HINT: When any of these DTCs are set, check the IAT by entering the following menus on the intelligent tester: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / INTAKE AIR.
MONITOR DESCRIPTION
The ECM monitors the sensor voltage and uses this value to calculate the Intake Air Temperature (IAT). When the sensor output voltage deviates from the normal operating range, the ECM interprets this as a malfunction in the IAT sensor and sets a DTC.
Example:
If the sensor output indicates -40°C (-40°F) for 0.5 seconds or more, the ECM determines that there is an open in the IAT sensor circuit, and sets DTC P0113. Conversely, if the sensor output indicates more than 140°C (284°F) for 0.5 seconds or more, the ECM determines that there is a short in the sensor circuit, and sets DTC P0112.
If the malfunction is not repaired successfully, a DTC is set 0.5 seconds after the engine is next started.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
P0110:
P0112:
P0113:
COMPONENT OPERATING RANGE
WIRING DIAGRAM
INSPECTION PROCEDURE
HINT:
- If other DTCs relating to different systems that have terminal E2 as the ground terminal are output simultaneously, terminal E2 may have an open circuit.
- Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air-fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.
PROCEDURE
1. READ OUTPUT DTC
(a) Connect the intelligent tester to the DLC3.
(b) Turn the ignition switch to the ON position and turn the tester on.
(c) Select the following menu items: DIAGNOSIS / ENHANCED OBD II / DTC INFO / CURRENT CODES.
(d) Read the DTCs.
Result:
C -- READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN ECM)
B -- READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS)
A -- Continue to next step.
2. READ VALUE USING INTELLIGENT TESTER (INTAKE AIR TEMPERATURE)
(a) Connect the intelligent tester to the DLC3.
(b) Turn the ignition switch to the ON position.
(c) Turn the tester on.
(d) On the tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / INTAKE AIR.
(e) Read the value displayed on the tester.
Standard:
Same as the actual Intake Air Temperature (IAT).
Result:
HINT:
- If there is an open circuit, the intelligent tester indicates -40°C (-40°F).
- If there is a short circuit, the intelligent tester indicates 140°C (284°F) or higher.
C -- CHECK FOR INTERMITTENT PROBLEMS
B -- READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS)
A -- Continue to next step.
3. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN WIRE HARNESS)
(a) Disconnect the M1 MAF meter connector.
(b) Connect terminal THA of the MAF meter wire harness side connector.
(c) Connect the intelligent tester to the DLC3.
(d) Turn the ignition switch to the ON position and turn the intelligent tester on.
(e) Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / INTAKE AIR.
(f) Read the value.
Standard temperature:
140°C (284°F) or more
OK -- CONFIRM GOOD CONNECTION TO SENSOR. IF OK, REPLACE MASS AIR FLOW METER
NG -- Continue to next step.
4. READ VALUE USING INTELLIGENT TESTER (CHECK FOR OPEN IN ECM)
(a) Disconnect the M1 MAF meter connector.
(b) Connect terminals THA and E2 of the E7 and E8 ECM connectors.
HINT: Before checking, perform visual and contact pressure checks on the ECM connector.
(c) Connect the intelligent tester to the DLC3.
(d) Turn the ignition switch to the ON position.
(e) Turn the tester on.
(f) On the tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / INTAKE AIR.
(g) Read the value displayed on the tester.
Standard temperature:
140°C (284°F) or higher
NG -- CONFIRM GOOD CONNECTION TO ECM. IF OK, REPLACE ECM
OK -- REPAIR OR REPLACE HARNESS OR CONNECTOR
5. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN WIRE HARNESS)
(a) Disconnect the M1 MAF meter connector.
(b) Connect the intelligent tester to the DLC3.
(c) Turn the ignition switch to the ON position.
(d) Turn the tester on.
(e) On the tester, select the following menu items: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / INTAKE AIR.
(f) Read the value displayed on the tester.
Standard temperature:
-40°C (-40°F)
OK -- REPLACE MASS AIR FLOW METER
NG -- Continue to next step.
6. READ VALUE USING INTELLIGENT TESTER (CHECK FOR SHORT IN ECM)
(a) Disconnect the E7 and E8 ECM connectors.
(b) Connect the intelligent tester to the DLC3.
(c) Turn the ignition switch to the ON position.
(d) Turn the tester on.
(e) Enter the following menus: DIAGNOSIS / ENHANCED OBD II / DATA LIST / ALL / INTAKE AIR.
(f) Read the value displayed on the tester.
Standard temperature:
-40°C (-40°F)
NG -- REPLACE ECM
OK -- REPAIR OR REPLACE HARNESS OR CONNECTOR