System Description
SYSTEM DESCRIPTION1. GENERAL
a. Air Conditioning Unit
- The evaporator body has been coated with a type of resin that contains an antibacterial agent in order to minimize foul odor and the propagation of bacteria.
- An MS (Multi-tank, Super-slim) structure evaporator consists of the top and bottom tanks and inner fin.
- A compact, lightweight, and highly efficient straight flow (full-path flow) aluminum heater core is used.
- A 2-way flow type air conditioning unit changes the 2-way flow operation if specified conditions are met. Under 2-way flow operation, the system introduces external air and internal air simultaneously as follows: 1) warm internal air is discharged to the foot area; and 2) fresh, dry, external air is discharged to the upper area. Thus, it realizes both excellent heating performance and demisting performance.
- The PTC (Positive Temperature Coefficient) heater contains electrodes that are interposed with a PTC element, to which current is applied in order to warm the air that passes through the fin.
b. Other Equipment
- The compressor is a continuously variable capacity type in which its capacity varies in accordance with the cooling load of the air conditioner.
- The A/C amplifier assembly is equipped with a self-diagnosis function. If there is a malfunction in the system, it stores DTC(s) in its memory.
- When the A/C amplifier assembly uses the CAN communication line, necessary data is shared with the ECM.
Mode Position And Damper Operation (Part 1):
Mode Position And Damper Operation (Part 2):
2. MODE POSITION AND DAMPER OPERATION
Air Outlets And Airflow Volume (Part 1):
Air Outlets And Airflow Volume (Part 2):
3. AIR OUTLETS AND AIRFLOW VOLUME