B1423
DTC B1423 Pressure Switch CircuitDESCRIPTION
DTC Detection Condition:
This DTC is output when refrigerant pressure is extremely low (0.176 MPa (1.8 kgf/sq.cm, 25 psi) or less) or extremely high (3.025 MPa (32.0 kgf/sq.cm, 455 psi) or more). The pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs refrigerant pressure signals to the A/C amplifier assembly. The A/C amplifier assembly converts the signals to pressure according to the sensor characteristics to control the compressor.
Wiring Diagram:
Step 1-2:
Step 2(continued)-3:
Step 4-6:
Step 6(continued):
INSPECTION PROCEDURE