Variable Valve Timing Actuator: Testing and Inspection
INSPECTIONINSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
a. Resistance inspection.
1. Using an ohmmeter, measure the resistance between the terminals.
Resistance: 6.9 to 7.9 Ohms at 20°C (68°F)
b. Movement inspection.
1. Connect the battery positive (+) lead to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
NOTE: Confirm the valve moves freely and does not stick in any position.
HINT: Foreign objects in the oil can cause subtle pressure leaks in the valve. The pressure leak will cause the cam to advance. This condition will usually set a DTC.