Brake Fluid Level Sensor/Switch: Testing and Inspection
INSPECT BRAKE FLUID LEVEL WARNING SWITCHa. Remove the reservoir tank cap and strainer.
b. Disconnect the connector.
c. Measure the resistance between the terminals.
Standard: Float up (switch off): 10 kOhms or higher
d. Use a syphon, etc. to take fluid out of the reservoir tank.
e. Measure the resistance between the terminals.
Standard: Float down (switch on): Below 1 Ohm
f. Pour the fluid back in the reservoir tank.