Programming and Relearning
CUSTOMIZE PARAMETERSBUZZER ON/OFF SETTING
a. Check that the ODO display is on, and turn the ignition switch off and then on. If other display is on, change it to the ODO display.
b. Within 2 to 6 seconds after turning the ignition switch ON, push the ODO/TRIP switch and hold it for 10 seconds or more.
c. Following the table, set the buzzer cancel setting.
HINT: The ODO/TRIP display changes from "b-on" to "b-off", entering the cancel mode.
d. During the cancel mode, each time the ODO/TRIP switch is pushed, the setting is switched between
*1 b-on and *2 b-off.
HINT:
*1 b-on: Cancel is invalid
*2 b-off: Cancel is valid
e. After the setting, the mode will be canceled by either not operating the switch for 10 seconds or more, or turning the ignition switch from ON to OFF.
HINT: The setting can be reset when reconnecting the battery connector or removing/installing the meter connector (Buzzer on).