Control Valve Body Assembly Removal
Control Valve Body Assembly Removal
1. Remove the fluid temperature sensor (32).
2. Disconnect the 5 solenoid wire connectors.
3. Remove the wiring harness assembly (78) from clamps.
4. Remove the 2 bolts (33 and 34), the fluid passage cover and fluid passage cover gasket.
5. Remove the 8 bolts (281-284).
6. While holding the valve body assembly (39), disconnect the manual valve connecting rod (336) from the manual valve lever (710) and remove the valve body assembly.
7. Remove the 2 transmission case fluid passage seals (84) and discard.