P0136
DTC P0136CIRCUIT DESCRIPTION
The heated oxygen sensor (HO2S) produces a voltage that varies between 100-900 mV under normal operating conditions. The engine control module (ECM) produces a bias voltage on the HO2S signal circuit of 420-480 mV. The reference ground for the sensor is provided through the ECM. The ECM monitors the signal voltage to determine if the exhaust is lean or rich. The oxygen sensor voltage is high when the exhaust is rich, and low when the exhaust is lean. The ECM constantly monitors the HO2S signal during the closed loop operation. If the ECM detects an HO2S voltage that stays below a specified value, DTC P0136 will set for bank 1 sensor 2 or DTC P0156 will set for bank 2 sensor 2.
CONDITIONS FOR RUNNING THE DTC
- No EVAP systems DTCs are set.
- The engine is running.
- The Battery Voltage parameter is more than 11 volts.
- The Loop Status bank 1 sensor 2 or Loop Status bank 2 sensor 2 parameter is Closed.
- The Fuel Level parameter is more than 10 percent.
- The calculated catalytic converter temperature is less than 940°C (1,724°F).
CONDITIONS FOR SETTING THE DTC
The ECM detects that the HO2S parameter is less than 40 mV for longer than 80 seconds.
ACTION TAKEN WHEN THE DTC SETS
- The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails.
- The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records.
CONDITIONS FOR CLEARING THE MIL/DTC
- The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail.
- A current DTC, Last Test Failed, clears when the diagnostic runs and passes.
- A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic.
- Clear the MIL and the DTC with a scan tool.
TEST