Intake Plenum Switchover Valve Solenoid
REMOVAL
1. Remove vacuum lines from solenoid.
2. Disconnect solenoid electrical connector.
3. Remove solenoid bolts.
4. Remove solenoid.
INSTALLATION
1. Install solenoid.
2. Install solenoid bolts.
Torque: 8 N.m (71 in-lbs)
3. Connect solenoid electrical connector.
4. Attach vacuum lines to solenoid.