Solenoid Test (Outlet Valves)
The Solenoid Test for outlet valves activates the selected hydraulic wheel circuit valves, placing them in the pressure release position. When in the pressure release position, the valve will allow wheel caliper pressure to be returned to the master cylinder circuit. This is done under ABS operating conditions because the EBTCM has determined that the wheel is moving too slowly, and holding additional master cylinder pressure from it has not allowed it to rotate at an appropriate speed. The scan tool commands the valve to these positions which should allow the technician to spin the wheel even though an assistant is applying pressure to the brake pedal.Perform the test as follows:
1. Ignition OFF
2. Install the scan tool.
3. Turn ignition to RUN.
4. Raise vehicle such that wheels are about six inches off the floor with the transmission in neutral.
5. Have an assistant press and hold the brake pedal.
6. Select Solenoid Test. Have an assistant command Release Pressure with the scan tool.
7. Attempt to move the wheel being tested by hand; it should move even though the assistant is applying pressure to the brake pedal. The wheels may be difficult to turn by hand, but can be moved if the system is working properly.