Installation
1. Apply sealant with Teflon P/N 21485278 or equivalent on threads before installing.
2. Install transaxle fluid temperature sensor.
Torque: 8 Nm (71 inch lbs.)
3. Connect electrical connector to transaxle fluid temperature sensor.
4. Install air box and install three air box bolts.
5. Install air induction system.
Torque: 10 Nm (89 inch lbs.)
6. Replace any fluid lost.